  • Motor Exhaust Gas Sulfur Analyzer

    MEXA-1170SX - HORIBA, Ltd.

    The MEXA 1170 SX is a new instrument used to measure sulfur for after treatment and transient lubricant oil consumption. The analyzer uses ultraviolet fluorescence (UVF) for detection and it can be operated in a total sulfur mode, analyzing sulfur oxides, hydrogen sulfide and all organic sulfur compounds. An inorganic sulfur mode will analyze hydrogen sulfide and the sulfur oxides. The final operational mode will analyze just the sulfur oxides. Any one of these modes can be selected by the user from a front panel interface.

  • Flue Gas Analyzer (Instrument Only)

    C160 - UEi Test & Measurement Instruments

    Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C160 Residential Combustion Analyzer is instrument only, easy to use with a rugged design, multiple sensor protections and altitude compensation. Essential information for installing and maintaining furnaces and boilers all in one device.

  • Industrial 4 Gas Combustion Analyzer

    K905 - UEi Test & Measurement Instruments

    Hand-held indusrial Combustion analyzer with Wireles communication option

  • Advanced IR Gas Analyzer For Process Monitoring

    T-Series - MKS Instruments

    T-Series Inline Gas Analyzer improves gas measurement accuracy over the traditional non-dispersive infrared (NDIR) analyzers using Tunable Filter Spectroscopy (TFS™), a spectroscopic scanning technique capable of generating slices of spectra in the infrared region. Each scan produces an absorption spectrum which is used to identify compounds and provide concentration values. TFS technology improves gas identification accuracy and selectivity by subtracting out spectra from interferent gases within the same infrared regions. This spectral processing capability also provides multi-component measurement.

  • Laser Spectroscopic Motor Exhaust Gas Analyzer

    MEXA-ONE IRLAM - HORIBA, Ltd.

    The MEXA-ONE IRLAM is an analyzer for the direct, simultaneous real-time measurement of the four relevant nitrogen-containing exhaust gas components NO, NO2, N2O and NH3.HORIBA's innovative infrared gas analysis technology, IRLAM™ (Infrared Laser Absorption Modulation), enables low-noise, high-precision measurement of four nitrogen compound gases (NO, NO2, N2O, NH3) in the low concentration range.

  • Laser Spectroscopic Motor Exhaust Gas Analyzer

    MEXA-ONE-QL-NX - HORIBA, Ltd.

    The MEXA-ONE-QL-NX is an analyzer for the direct, simultaneous real-time measurement of the four relevant nitrogen-containing exhaust gas components NO, NO2, N2O and NH3.The analyzer combines a light source based on the new quantum cascade technology (efficient lasers in the mid-infrared spectral region) with a precisely adjusted dual path cell to measure low concentrations with maximum sensitivity. The detection limit complies with current European legal requirements.Furthermore, the MEXA-ONE-QL-NX offers wide measuring ranges of up to 5000 ppm (for NO). By using extremely narrowband light sources and measuring under reduced pressure the cross-sensitivity to other exhaust gas components can be drastically minimized.The complete measuring system - including filtration - is specifically developed for the measurement of NH3 and thus guarantees a very fast NH3 rise time (T10-T90) of less than 5 seconds. The MEXA-ONE-QL-NX can be operated as a stand-alone analyzer or integrated into the MEXA-ONE software interface for user-friendly and simplified system operation.

  • Gas Filter Correlation Carbon Dioxide Analyzer

    Model T360 - Teledyne Monitor Labs

    The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.​The Model T360 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software​.​​​

  • ​Gas Filter Correlation Carbon Monoxide Analyzer​

    Model T300 - Teledyne Monitor Labs

    The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information, is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software​.​​

  • BET Flowing Gas Surface Area Analyzers

    SA-9600 Series - HORIBA, Ltd.

    The surface area of a material is, in many cases, as important as the chemical properties. As particle size decreases, surface area increases. Porosity of materials - from micropores to macropores - contribute even more to the total surface area. The interface at the surface is what defines how a solid reacts to other substances, be they gases, liquids, or solids.Surface area can impact shelf life, stability, dissolution and efficacy of pharmaceutical powders and tablets. Likewise, surface area can affect the rheological properties and hiding powers of pigments, paints, and coatings. It has a significant impact on the ability for materials like catalysts, adsorbents, filtration materials and air separation products to react in the designed application. Ceramics used in applications ranging from; dinner plates, to dental implants, to electronics, all are affected by surface area.

  • CO2 Isotope/ NH3 Trace Gas Analyzer

    LI-7825 - Li-Cor Environmental, Inc.

    The LI-7825 measures the four most abundant CO2 gas isotopologues in air and reports δ13C , δ17O , and δ18O with high precision and accuracy.

  • Precisive® 5 Application Specific Gas Analyzers

    MKS Instruments

    The Precisive® Gas Analyzer is a real-time gas analyzer based on MKS' unique Tunable Filter Spectroscopy (TFS™) platform. The Precisive suite of products are calibrated for the measurement of a wide range of gases across multiple process industries. The real-time, continuous measurement capability provides immediate analysis ensuring control of critical process parameters.

  • Mid-Range Gas Filter Correlation Carbon Monoxide Analyzer​

    Model T300M - Teledyne Monitor Labs

    The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance from low to high range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​​

  • ​Mid-Range Gas Filter Correlation Carbon Dioxide Analyzer​

    Model T360M - Teledyne Monitor Labs

    The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​

  • FTIR Exhaust Gas Analyzer Dilute Measurement Type

    FTX-ONE-CL - HORIBA, Ltd.

    Offers a 5Hz sampling rate and simultaneously measure the concentrations of multiple components including NH3, CH4 and CO2, engine diluted exhaust gas using the Fourier Transform Infrared (FTIR) method in combination with multivariate analysis algorithm.

  • FTIR Exhaust Gas Analyzer Direct Measurement Type

    FTX-ONE-CS/RS - HORIBA, Ltd.

    The FTX-ONE offers a 5Hz sampling rate and simultaneously measure the concentrations of multiple components including NH3, CH4, and CO2, from (engine) direct exhaust gas using the Fourier Transform Infrared (FTIR) method in combination with multivariate analysis algorithm.